CBXLF - CAT FOR 463-6-56 OR 463-6-57, X 439

  • MSDS: CBXLF
  • Manufacturer: AKZO COATINGS INC
  • Product Name: CAT FOR 463-6-56 OR 463-6-57, X 439
  • National Stock Number: 8010-00N071638
Product Identification

Product ID:CAT FOR 463-6-56 OR 463-6-57, X 439
MSDS Date:09/10/1987
FSC:8010
NIIN:00N071638
MSDS Number: CBXLF

Responsible Party
AKZO COATINGS INC
434 WEST MEATS AVE
ORANGE, CA 92665
US

Emergency Phone: 313-637-0400

Info Phone: 313-855-7313

Preparer: CHARLES L GRUBBS

Cage: 98502

Contractor
AKZO COATINGS INC
ORANGE, CA 92661 US

Telephone: 714-637-1750; CHEMTREC 800-424-9300

Cage: 98502

Ingredients

4.4

CAS: 71-36-3

RTECS: EO1400000

Fraction By Weight: 20-35%

OSHA PEL 100 PPM

ACGIH TLV: C 50 PPM, S

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


22.0

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 40-55%

OSHA PEL 200 PPM

ACGIH TLV: 50 PPM, S

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


9.5

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 25-40%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/150STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


OVEREXP HAS BEEN

RTECS: 9999999ZZ


HAVE SHOWN THAT MANY PETRO HYDROCARBONS POSE

RTECS: 9999999ZZ


AS PREC, EXPOS TO LIQS & VAPS OF PETRO PRODS SHOULD

RTECS: 9999999ZZ


LIVER ABNORM.

RTECS: 9999999ZZ


TO MATL HAS BEEN SUGGESTED AS CAUSE OF THE FOLLOWING

RTECS: 9999999ZZ


BLOOD CELL & LEUCOCYTE DISORDERS WHICH MAY RSLT IN

RTECS: 9999999ZZ


CHEMICAL REPRODUCTIVE HAZARDS. SEEL CONSULTATION

RTECS: 9999999ZZ


HAZARD LIST INFORMATION AND SAFE HANDLING AND

RTECS: 9999999ZZ


CUT EMPTY DRUM. DO NOT HANDLE UNTIL MFR'S

RTECS: 9999999ZZ


HEATING. REMOVE DECOMP PRODS FORMED DURING

RTECS: 9999999ZZ


NEEDED TO AVOID RPTD/FREQUENT SKIN CONT,

RTECS: 9999999ZZ


AND FULL LENGTH FACESHIELD .

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THE FOLLOWING HAZ HAVE BEEN REPORTED
TO BE ASSOC W/INDIVIDUAL COMPONENTS OF THIS PROD. THESE HAZ MAY NOT
ALL BE ASSOC W/FINISHED PROD. ACUTE: EXCESS INHAL OF VAPS CAN CAUSE
NASAL & RESP TRACT IRRIT, D IZZ, WEAK, FATG, NAUS, HDCH, POSS
UNCON, & EVEN ASPHY. EYES: IRRIT. CONT MAY CAUSE EYE BURNS/CORNEAL
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: INJURY. MAY CAUSE SEV IRRIT, REDNESS,
TEARING, BLURRED VISION, & SENSATION OF SEEING HALOS AROUND LIGHTS.
PRLNG CONT W/SKIN MAY LEAD TO EXTRACTION OF NATRL OILS W/RSLT MILD
IRRIT. INGEST: CA N CAUSE GI IRRIT, NAUS, VOMIT, & DIARR.ASPIR OF
MATL INTO LUNGS CAN CAUSE CHEM PNEUMIT WHICH CAN BE FATAL. (SUP
DAT)
Medical Cond Aggravated by Exposure:NONE EXPECTED.

First Aid

First Aid:INHALATION: MOVE TO FRESH AIR. GIVE ARTIFICIAL RESPIRATION IF
NECESSARY. SKIN: WASH WITH SOAP AND WATER. EYES: FLUSH WITH WATER
FOR AT LEAST 15 MINUTES, CONSULT MD. INGESTION: DRINK ONE OR TWO
GLASSES OF WATER TO DILUTE. DO NOT INDUCE VOMITING. CONSULT MD OR
POISON CONTROL CENTER IMMEDIATELY. TREAT SYMPTOMATICALLY.

Fire Fighting

Flash Point Method:TCC
Flash Point:40.0F,4.4C
Lower Limits:1.0%
Extinguishing Media:USE FOAM, CARBON DIOXIDE, DRY CHEMICALS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . WATER MAY BE INEFFECTIVE. WATER SHOULD BE
USED TO COOL CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM
HEAT, SPARKS, ELEC EQUIP & OPEN FLAME. CLSD CONTRS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. APPLICATION TO HOT (SUP DAT)

Accidental Release

Spill Release Procedures:REFER TO PROTECTIVE MEASURES SECTIONS. REMOVE
ALL SOURCES OF IGNITION. AVOID BREATHING VAPORS. VENTILATE AREA.
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE CONTRS OUT OF SUN & AWAY FROM
HEAT, SPARKS & OPEN FLAMES. CLOSE CONTRS AFTER EACH USE. CONSULT
NFPA CODE FOR ADDITIONAL STORAGE REQUIREMENTS.
Other Precautions:DO NOT TAKE INTERNALLY. USE APPRVD BONDING &
GROUNDING PROC. OBSERVE LABEL PREC. KEEP CLOSURES TIGHT & CONTR
UPRIGHT TO PVNT LEAKAGE. NEVER USE PRESS TO EMPTY-DRUM IS NOT A
PRESS VESSEL. AVOID BRTHG S ANDING DUST. DO NOT WELD/FLAME (ING 12)

Exposure Controls

Respiratory Protection:ADEQUATE VENTILATION IS REQUIRED. USE NIOSH/MSHA
APPROVED RESPIRATOR DEVICE. SEE YOUR SAFETY EQUIPMENT SUPPLIER FOR
EVALUATION AND RECOMMENDATION. IN CONFINED AREAS USE NIOSH/MSHA
APPROVED AIRLINE RES PIRATOR OR HOOD.
Ventilation:PROVIDE SUFFICIENT VENT TO KEEP VAP CONC BELOW GIVEN TLV &
LEL. FOR BAKING FINISHES, EXHST VAP EMITTED ON (ING 13)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (ING 15)
Other Protective Equipment:EMER EYEWASH & DELUGE SHOWER MEETING ANSI
DESIGN CRITERIA . USE CHEM RESIST APRON, BOOTS/OTHER CLTHG IF (ING
14)
Work Hygienic Practices:WASH HANDS BEFORE EATING, SMOKING OR USING
WASHROOM.
Supplemental Safety and Health
EXPLO HAZ: SURF REQS SPEC PREC. DURING EMER CNDTNS OVEREXP TO DECOMP
PROD MAY CAUSE HLTH HAZ. SYMPS MAY NOT BE IMMED APPARENT, OBTAIN
MED ATTN. EFTS OF OVEREXP: NOTICE: INTENTIONAL MISUSE BY DELIBERAT
ELY CONCG & INHALING CONTENTS MAY BE HARMFUL/FATAL. RPTS HAVE ASSOC
RPTD & PRLNG OCCUP OVEREXP TO SOLV W/PERM (ING 4)

Chemical Properties

Boiling Pt:B.P. Text:>230F,>110C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.86
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER
Percent Volatiles by Volume:95.8

Stability

Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
SMOKE, OXIDES OF NITROGEN.

Disposal

Waste Disposal Methods:INCINERATE IN AN APPROVED FACILITY, DO NOT
INCINERATE CLOSED CONTAINERS. DISPOSE OF IN ACCORDANCE WITH
FEDERAL, STATE, AND LOCAL POLLUTION CONTROL REQUIREMENTS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.